select F2 Program and MDI screen.

select MDI mode in the bottom right corner of your screen.

type in G55 followed by select run. you should notice above your f2 pregame and MDI screen your machine will state workplace coordinate G55

you will then need to set your X and Y coordinates for your workplace coordinate as normal.

For Z instead of calibrating to the rear you will use your probe function and set it so the lowest tip on the tool touches off on the top of the tool. (please note do not use the center of the tool or you will break your calibrator.)