2 wires need to be installed


The first needs to be installed from the MCM on the Spindle to a 24V- Connection on the masso companion board.


The Second needs to be installed from MO2 to an input on the masso companion board. This input will be the input signal for the alarm itself.



On the VFD you will need to change the parameters to put out a spindle alarm, to do this Press the PRGM Button to open the parameters and Navigate to F2 then press the mode button to continue and navigate to F2.20.  This setting needs to be changed to 3 to enable the fault output.



After this is complete you can change the setting of the input on the masso that you used earlier to Spindle Motor Alarm Input and your machine will now have an operational spindle alarm.