MIRA - fitting machine through door (on its side)

Modified on Tue, 13 Dec 2022 at 01:57 PM

1. Remove items from inside the bed of the machine.
2. Ziptie the laser head to one side of the z axis through the slots on the back of the frame. See image below.

3.Open back hatch using keys provided in kit and check the laser tube before moving. Check for visible cracks on the outer and inner tube. Also ensure the clamps are secure over the tube. See image below:


4. Strap/ tape the front glass down to ensure the door does not open while moving. Also ensure the chiller is on the bottom of the dolly as it is the heavier side and if there is any water residue it will not drip through the machine.


NOTE: you can empty the chiller to take out some of the water weight for moving the Mira. Just remember to refill the chiller afterwards. 

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons

Feedback sent

We appreciate your effort and will try to fix the article